This Product is discontinued, please contact us if you are still interested. An alternative is e.g:

Rack-mount Meter

The X1-RM combines the same powerful electronic design as the hand held meters in a rack-mountable housing for integration into 19” 3HE racks.


Simple to Use

Operating the X1 is simple. The meter set-up is supported by an easy to use menu. The menu allows selection of the operating mode, the detector and measurement parameter. Once set-up all settings are stored and recalled on next power-up unless reinitialized. Measurement values are displayed in absolute quantities for the particular detector connected.


Four-channel Meter

The unique feature of all X1s is their capability to operate multi-cell detector heads with up to four photodiodes with all four signals displayed or read-out via the USB or RS232 interfaces.


Multipurpose Light Measurement Instrument

All X1s can be combined with most of the Gigahertz-Optik single cell or multi cell light detector heads for use in a wide application range of radiometric, photometric and colorimetric measurements.


Menu Guide

Menu item Submenu item Function
1. Mode CW Measures respective of any offset and calibration factors programmed
  Dose Accumulates the single readings as exposure for measured quantity
  CIE Yxy & T Measures the CIE Color Values Yxy & T
  CIE Yuv & T Measures the CIE Color Values Yuv & T
2. Setup Zero Adjust Performs a zero adjustment of the internal amplifier and ADC
  Integration Sets the measurement (integration) time
  Meas. Mode Selects measurement mode (DC, Pulse Synchronisation, Peak-Peak)
  Dose Time Sets max. dose measurement time
4. Detector   Selects calibration data to calculate the measurement result
5. Offset   Performs an automatic offset adjustment ("Offset = CW" or "Offset = 0")
6. Range   Sets the measurement range (auto, manual)
X1-RM
General
Short description

Optometer for the integration in 19 Inch racks. Individual configuration as photometer, RGB-luminous color meter, radiometer, UV-radiometer, LASER-powermeter etc. with the detector heads supplied.  

Main features

Robust and metal shielded Optometer for the use in 19 inch rack-mounts. Four measurement chanels in multiplex operation for use with single and multi-chanel detectors heads. Device RS485 Interface. I/O interfaces. Back illuminated display with four lines. USB or DC-voltage powered. USB-Interface. User Software and Software development kit available.

Measurement range

Wide dynamic current measurement range from 0.1 pA (noise equivalent signal) up to 200 µA. Seven gain ranges with manual or automatic selection. Measurement range in absolute units with given by the detector heads responivity and calibration. 

typical applications

Measurement device for system integrations.  

Calibration

Calibration and comparison of the current responsivity in each of the seven gain ranges. Memory for calibration data of several detector heads for measuremen in the absolute unit of the selected detector head. 

Product
Power Supply

(7 - 20) VDC / 100 mA; plug 5,5 / 2,5 mm / 10 mm (+ at middle contact)

Display

LCD graphic display 97x32 pixel, display area 14.3 mm x 35.8 mm
switchable LED-backlight, text display 4 rows each 14 characters

Detector interface

9pin MDSM9 socket, 4 inputs

Parameter adjustment

Remote control or front panel buttons (menu), adjusted values permanently stored in Eeprom

Front panel control

3 buttons, menu system

Interface

USB V1.1 (HID Device)
RS485 or RS232 (factory set) / 19200 Baud (Slave Mode)

Analog input

4 voltage measurement channels; (0 - 20) VDC, input resistance 1 MOhm, 12 bit ADC

CW integration time

1 ms – 1 s

Miscellaneous
temperature range

operation: 5 °C to 40 °C

storage: -10 °C to 50 °C

Dimensions

65.5 mm x 105 mm x 80 mm

19", 3HE, 13TE

Weight

500 g

Type Description File-Type Download
Datasheet X1-RM PDF
Produktname Product Image Description Show product
VL-3701 Detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 3 %, f2 ≤ 1.5 %, 0.5 nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

VL-3702 Detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 6 %, f2 ≤ 3 %, 0.5 nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

VL-3704 Detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 5 %, f2 ≤ 3 %, 20pA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

VL-3705 Detector head for the measurement of scotopic illuminance in Lux [lx].

Features: f1 ≤ 5 %, f2 ≤ 3 %, 0.2nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

PD-9310A High sensitive detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 3 %, 2.8nA/lx, 20mm diffuser, for the usage with optometers and amplifiers, calibration certificate

PD-9310B High sensitive detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 6 %, 2.8nA/lx, 20mm diffuser, for the usage with optometers and amplifiers, calibration

PD-9310B-N Very high sensitive detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 3 %, 28nA/lx, no diffuser, for the usage with optometers and amplifiers, calibration

VL-1101 + UMPA-0.5-11-RD Detector head Module detector head for the measurement of photopic illuminance in Lux [lx].

Features: UMPA adapter for usage with integrating spheres, for the usage with optometers and amplifiers, calibration certificate

VL-3701 with SRT-M37-L Detector head to measure the photopic illuminance in lx and the luminance in cd/m².

Features: front lenses with 1°, 2° or 5° viewing angle, for the usage with Optometers and amplifiers, calibration certificate

PD-9310 with SRT-M37-L High sensitive detector head to measure the photopic luminance in cd/m².

Features: front lense for 1°, 2°, 5° or 10° viewing angle, for the usage with Optometers and amplifiers, calibration certificate

VL-1101 Photometric detector head with VL-11 mount.

Features: modular detector for use with integrating spheres, front lenses etc. For use with optometers and signal amplifiers

PD-9304 Universal detector head for LASER power, illuminance and 400-1100 nm iiradiance.

Features: Si-photodiode with 1 cm², exchange able filters and cosine diffuor, for the usage with optometers and signal amplifiers

RW-3701 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 400-500nm (BLUE), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3702 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 700-800nm (RED), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3703 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 400-800nm (VIS), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3704 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 800-1000nm (NIR), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
RW-3705 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 400-1000nm (VISNIR), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3708 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 950-1700nm (NIR), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3701 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 315-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
UV-3702 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 280-315nm (UV-B), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3703 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 200/250-280nm (UV-C), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3710 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 320-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
UV-3711 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 280-320nm (UV-B), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3716 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 305-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
UV-3717 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 315-400nm (UV-A), low cross talk from radiation > 400 nm, cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3719 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 250-400nm (UV), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3720 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 240-320nm (UV), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3718 Detector head for the measurement of high irradiance of UV-C 254nm radiation in W/m².

Features: pre-aging for long time stability, cosine field-of-view, metal shielded cable, for the usage with optometers and amplifiers, calibration certificate.

RCH-102 Detector head for high intensity irradiation in UV or blue light curing processes.

Features: Separate light integrator and detector with rigid fiber coupling, (320-460)nm UVABLUE responsivity, wide viewing angle, for the usage with optometers and amplifiers, calibration certificate.
PD-11 series Detector head with DP-11 mount.

Features: modular detector for use with integrating spheres, front lenses etc, Si, SiLP, InGaAs, SiC, GaP photodiodes, for use with optometers and signal amplifiers

UV-3706 Detector head to measure irradiance W/m2 in Bilirubin phototherapy.

Features: Bilirubin actinic responsivity, cosine field-of-view, for usewith optometers, calibration certificate.

UV-3711-308 Detector head for the measurement of irradiance of 308nm Eximer Lasers in W/m².

Features: flat spectral responsivity besite 308nm. cosine field-of-view, dose measurement in conjuntion with P-9710-2 optometer, calibration certificate

UV-3709 Detector for Blue-light hazard measurements.

Features: Single-cell detector, BLH actinic irradiance, for the use with optometer, calibration certificate

UV-3725 Detector for the measurement of UV-C 254 nm irradiance in air disinfection applications.

Features: wide dynamic range for UV hazard and effective irradiance, wide angle cosine F.O.V. for straylight measurements, for the usage with optometers, calibration certificate.
RW-37 with SRT-M37-L Detector heads to measure the irradiance in W/m² and the radiance in W/(m²*sr).

Features: front lenses with 1°, 2° or 5° viewing angle, for the usage with Optometers and amplifiers, calibration certificate
S-SDK-X20 Software Development Kit for X20 variants (X1 and HCT99).
S-X1 Application software for X1 variants.
BTH-19 Bench-top and rack housing for 3HE rack modules.

Features: The bench-top housings are available in half, third or full 19” widths. Power supply modules for (110-230) V, 50/60 Hz with low DC voltages for both external devices and those within the housing.
Article-Nr Modell Description Request / Compare
Product
15296732 X1-RM

Meter and manual

Options
Light Detectors

Please check the light detector datasheets for specification and purchasing information

Software
15298071 S-SDK-X20

For software implementation of the X20 optometer board or X1 device into custome made software. Supply of .dll's and LabView VI's for device communication.

15298167 S-X1

User software for the X1

Accessories
15296381 X1-Z02

Adapter cable (2m) to connect light detectors with -1 BNC connector to the -4

15296387 X1-Z03

Adapter to connect up to four detectors with BNC connector to X1

15297973 X1-Z04

Adapter cable 12inch with ITT (-4) connector for X1. Al box with -4 socket

15298036 X1-Z05

Adapter cable to connect light detectors with -2 calibration data connector to the ITT (-4) socket of the optometer X1 1. Cable length 0.2 m.

15295292 BHO-04

Hard case for meter and accessories

15295239 BHO-05

Hard case for meter and accessories

15295680 BHO-06

Hard case for meter and accessories

15297539 BHO-11

Hard case for meter and accessories

15298236 BHO-15

Hard case for meter and accessories

Product tags


Similar products