This Product is discontinued, please contact us if you are still interested. An alternative is e.g:

System Integration Meter

The X1-PCB is remote-control-only variant of the X1 hand held meter with housing and no display.


USB Powered

In remote control operation the X11 is powered through the USB or RS232 interface (special adapter cable).


Four-channel Meter

The unique feature of all X1s is their capability to operate multi-cell detector heads with up to four photodiodes with all four signals displayed or read-out via the USB or RS232 interfaces.


Multipurpose Light Measurement Instrument

All X1s can be combined with most of the Gigahertz-Optik single cell or multi cell light detector heads for use in a wide application range of radiometric, photometric and colorimetric measurements.

X1-PCB, X1-PCBCL for System Integration
Product
Power Supply

Powered by USB-Interface or by RS232 with external +5VDC with adapter cable

Detector interface

9pin MDSM9 socket, 4 inputs

Measurement range

Seven (200 μA to 0.1 pA) manual or auto range

CW integration time

1 ms - 1 s

Offset correction

Correction range transcending

Remote Control

Remote control, set values permanently stored (eeprom)

Calibration information

up to 256 Datasets stored in Eeprom

Miscellaneous
temperature range

Operation: 5 °C to 40 °C
Storage: -10 °C to 50 °C

Type Description File-Type Download
Datasheet X1-PCBC PDF
Produktname Product Image Description Show product
VL-3701 Detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 3 %, f2 ≤ 1.5 %, 0.5 nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

VL-3702 Detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 6 %, f2 ≤ 3 %, 0.5 nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

VL-3704 Detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 5 %, f2 ≤ 3 %, 20pA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

VL-3705 Detector head for the measurement of scotopic illuminance in Lux [lx].

Features: f1 ≤ 5 %, f2 ≤ 3 %, 0.2nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

PD-9310A High sensitive detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 3 %, 2.8nA/lx, 20mm diffuser, for the usage with optometers and amplifiers, calibration certificate

PD-9310B High sensitive detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 6 %, 2.8nA/lx, 20mm diffuser, for the usage with optometers and amplifiers, calibration

PD-9310B-N Very high sensitive detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 3 %, 28nA/lx, no diffuser, for the usage with optometers and amplifiers, calibration

VL-1101 + UMPA-0.5-11-RD Detector head Module detector head for the measurement of photopic illuminance in Lux [lx].

Features: UMPA adapter for usage with integrating spheres, for the usage with optometers and amplifiers, calibration certificate

VL-3701 with SRT-M37-L Detector head to measure the photopic illuminance in lx and the luminance in cd/m².

Features: front lenses with 1°, 2° or 5° viewing angle, for the usage with Optometers and amplifiers, calibration certificate

PD-9310 with SRT-M37-L High sensitive detector head to measure the photopic luminance in cd/m².

Features: front lense for 1°, 2°, 5° or 10° viewing angle, for the usage with Optometers and amplifiers, calibration certificate

VL-1101 Photometric detector head with VL-11 mount.

Features: modular detector for use with integrating spheres, front lenses etc. For use with optometers and signal amplifiers

PD-9304 Universal detector head for LASER power, illuminance and 400-1100 nm iiradiance.

Features: Si-photodiode with 1 cm², exchange able filters and cosine diffuor, for the usage with optometers and signal amplifiers

RW-3701 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 400-500nm (BLUE), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3702 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 700-800nm (RED), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3703 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 400-800nm (VIS), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3704 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 800-1000nm (NIR), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
RW-3705 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 400-1000nm (VISNIR), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3708 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 950-1700nm (NIR), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3701 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 315-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
UV-3702 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 280-315nm (UV-B), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3703 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 200/250-280nm (UV-C), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3710 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 320-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
UV-3711 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 280-320nm (UV-B), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3716 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 305-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
UV-3717 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 315-400nm (UV-A), low cross talk from radiation > 400 nm, cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3719 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 250-400nm (UV), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3720 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 240-320nm (UV), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3718 Detector head for the measurement of high irradiance of UV-C 254nm radiation in W/m².

Features: pre-aging for long time stability, cosine field-of-view, metal shielded cable, for the usage with optometers and amplifiers, calibration certificate.

RCH-102 Detector head for high intensity irradiation in UV or blue light curing processes.

Features: Separate light integrator and detector with rigid fiber coupling, (320-460)nm UVABLUE responsivity, wide viewing angle, for the usage with optometers and amplifiers, calibration certificate.
PD-11 series Detector head with DP-11 mount.

Features: modular detector for use with integrating spheres, front lenses etc, Si, SiLP, InGaAs, SiC, GaP photodiodes, for use with optometers and signal amplifiers

UV-3706 Detector head to measure irradiance W/m2 in Bilirubin phototherapy.

Features: Bilirubin actinic responsivity, cosine field-of-view, for usewith optometers, calibration certificate.

UV-3711-308 Detector head for the measurement of irradiance of 308nm Eximer Lasers in W/m².

Features: flat spectral responsivity besite 308nm. cosine field-of-view, dose measurement in conjuntion with P-9710-2 optometer, calibration certificate

UV-3709 Detector for Blue-light hazard measurements.

Features: Single-cell detector, BLH actinic irradiance, for the use with optometer, calibration certificate

UV-3725 Detector for the measurement of UV-C 254 nm irradiance in air disinfection applications.

Features: wide dynamic range for UV hazard and effective irradiance, wide angle cosine F.O.V. for straylight measurements, for the usage with optometers, calibration certificate.
RW-37 with SRT-M37-L Detector heads to measure the irradiance in W/m² and the radiance in W/(m²*sr).

Features: front lenses with 1°, 2° or 5° viewing angle, for the usage with Optometers and amplifiers, calibration certificate
S-SDK-X20 Software Development Kit for X20 variants (X1 and HCT99).
S-X1 Application software for X1 variants.
Article-Nr Modell Description Request / Compare
Product
15296854 X1-1

Meter, 2 x 1.5 V AA batteries, USB cable, manual

15297419 X1-2

Meter, 2 x 1.5 V AA batteries, USB cable, manual

15296732 X1-RM

Meter, manual

15297298 X1-PCB

PCB, USB interface, no metal housing, manual

15297295 X1-PCBCL

Meter with RS232 interface, metal housing, manual

15297296 X1-PCBCL-RM

Meter with RS232 interface, metal housing with rack mount face plate, manual

15297297 X1-PCBCL-PM

Meter with RS232 interface, metal housing with “L” bracket, manual

Options
Light Detectors

Please check the light detector datasheets for specification and purchasing information

15298167 S-X1

X1 user software

15298071 S-SDK-X20

For software implementation of the X20 optometer board or X1 device into custome made software. Supply of .dll's and LabView VI's for device communication.

Accessories
15296381 X1-Z02

Adapter cable (2m) to connect light detectors with -1 BNC connector to the -4

15296387 X1-Z03

Adapter to connect up to four detectors with BNC connector to X1

15297973 X1-Z04

Adapter cable 12inch with ITT (-4) connector for X1. Al box with -4 socket

15298036 X1-Z05

Adapter cable to connect light detectors with -2 calibration data connector to the ITT (-4) socket of the optometer X1 1. Cable length 0.2 m.

15295292 BHO-04

Hard case for meter and accessories

15295239 BHO-05

Hard case for meter and accessories

15295680 BHO-06

Hard case for meter and accessories

15297539 BHO-11

Hard case for meter and accessories

15298236 BHO-15

Hard case for meter and accessories


Similar products