This Product is discontinued, please contact us if you are still interested. An alternative is e.g:

Cost Effective Application Solution 

The PD-11 series detectors are designed as modular light detectors to be combined with integrating spheres, optics, filters and mechanical components to configure complete light detection assemblies. Their mechanical interface makes mounting or adding other components easy and flexible.

Detectors for use with Integrating Spheres 

The PD-11 series detectors with a housing diameter of only 11mm are compact in size and fit directly onto the DP-11 detector port of the UP series integrating spheres or can be mounted to most Gigahertz-Optik integrating spheres using the UMPA-0.5/11 port adapter. 

Traceable Calibration 

Optional calibration is available by Gigahertz-Optik’s Calibration Laboratory for Optical Radiation Quantities.
PD-1101 with Compact Size Integrating Sphere
PD-1101 Typical Spectral Responsivity Si Photodiode
PD-1102, PD-1103, PD-1104 Typical Spectral Responsivity. InGaAs Photodiode
PD-1105 Spectral Responsivity SiC Photodiode
PD-1106, PD-1107, PD-1108 Typical Spectral Responsivity. Low-profile Si Photodiode
PD-1109 Typical Spectral Responsivity GaP Photodiode
Calibration
Calibration

Calibration of the spectral responsivity from 250 nm to 1100nm or spectral responsivity range of detector in calibration (min. sensing area size required)

Calibration

Calibration of the spectral responsivity from 800 nm to 1800nm (min. sensing area size required)

Calibration of the relative spectral responsivity from 250 nm to 1100 nm

Calibration of the relative spectral responsivity from 250 nm to 550 nm

Calibration of the relative spectral responsivity from 800 nm to 1800 nm

Specification
PD-1101

 

Spectral Response

UV Enhanced Si 250 nm - 1100 nm

Sensing Area

13 mm², 3.6 mm x 3.6 mm

Typical Responsivity

0.15 A/W @ 350 nm
0.5 A/W @ 900 nm

Max. signal current

1 mA

Min. signal current

depends on optometer

Temperature range

(5 - 40) °C

Cable Length

2 m

Plug Type

-1,-2,-4

PD-1102

 

Spectral Response

InGaAs 800 nm -1800 nm

Sensing Area

0.07 mm², 0.3 mm Ø

Typical Responsivity

0.85 A/W @ 1350 nm
0.95 A/W @ 1500 nm

Max. signal current

1 mA

Min. signal current

depends on optometer

Temperature range

(5 - 40) °C

Cable Length

2 m

Plug Type

-1,-2,-4

PD-1103

 

Spectral Response

InGaAs 800 nm - 1800 nm

Sensing Area

0.79 mm², 1 mmØ

Typical Responsivity

0.85 A/W @ 1350 nm
0.95 A/W @ 1500 nm

Max. signal current

1 mA

Min. signal current

depends on optometer

Temperature range

(5 - 40) °C

Cable Length

2 m

Plug Type

-1,-2,-4

PD-1104

 

Spectral Response

InGaAs 800 nm - 1800 nm

Sensing Area

7.1 mm², 3 mmØ

Typical Responsivity

0.85 A/W @ 1350 nm
0.95 A/W @ 1500 nm

Max. signal current

1 mA

Min. signal current

depends on optometer

Temperature range

(5 - 40) °C

Cable Length

2 m

Plug Type

-1,-2,-4

PD-1105

 

Spectral Response

SiC 215 nm - 360 nm

Sensing Area

1.55 mm², 1.25 mm x 1.25 mm

Typical Responsivity

0.16 A/W @ 270 nm

Max. signal current

50 µA

Min. signal current

depends on optometer

Temperature range

(5 - 40) °C

Cable Length

2 m

Plug Type

-1,-2,-4

PD-1109
Spectral Response

GaP 250 nm - 550 nm

Sensing Area

1.21 mm², 1.1 mm x 1.1 mm

Typical Responsivity

0.4 A/W @ 445 nm

Max. signal current

0.1 mA

Min. signal current

depends on optometer

Temperature

(5 - 40) °C

Cable Length

2 m

Plug Type

-1,-2,-4

PD-1112

 

Spectral Response

GaAsP 200 nm - 680 nm

Sensing Area

5.2 mm², 2.3 mm x 2.3 mm

Typical Responsivity

0.035 A/W @ 254 nm
0.17 A/W @ 560 nm
0.17 A/W @ 633 nm

Max. signal current

1 mA

Min. signal current

depends on optometer

Temperature

(5 - 40) °C

Cable Length

2 m

Plug Type

-1,-2,-4

PD-1113

 

Spectral Response

GaAsP 400 nm - 760 nm

Sensing Area

7.3 mm², 2.3 mm x 2.3 mm

Typical Responsivity

0.22 A/W @ 560 nm
0.29 A/W @ 633 nm

Max. signal current

1 mA

Min. signal current

depends on optometer

Temperature range

(5 - 40) °C

Cable Length

2 m

Plug Type

-1,-2,-4

PD-1115

 

Spectral Response

Si PIN 400 nm - 1050 nm

Sensing Area

Ø 0,8 mm

Typical Responsivity

0,5 A/W @ 900 nm

Max. signal current

1 mA

Min. signal current

depends on optometer

Temperature range

(5 - 40) °C

Cable Length

2 m

Plug Type

-1,-2,-4

Graphs
spectral responsivity

PD12

Type Description File-Type Download
Datasheet PD-11 series PDF
Produktname Product Image Description Show product
P-9710 High-quality device for measurement of CW-, single pulse and modulated radiation.

Features: Optometer for all detector heads with calibration data plug. Measurement modes: CW, pulse energy, dose, peak-to-peak, effective luminous intensity (Blondel-Rey), data logger, battery, main power, RS232
X1 Four-channel USB optometer designed for mobile use.

Features: Compact device for use with all photometric, radiometric, colorimetric, plant-physiologic and photo-biologic measurement heads from Gigahertz-Optik. USB interface. Battery operation or power supply USB.
X1-RM Optometer in 3HE housing for use in 19” racks.

Features: Its USB and RS232 remote interface and two additional RS232 device interfaces make the device highly flexible when it comes to system integration. Its four signal inputs enable use with all photometric, radiometric, colorimetric, plant-physiologic and photo-biologic measurement heads from Gigahertz-Optik.
X1-PCB Optometer module.

Feature: The X1 optometer is available as a printed circuit board either with or without a housing and is suited for applications that do not require a keyboard or display. Four signal inputs enable connection with all measuring heads from Gigahertz-Optik.
P-2000 Two-channel optometer.

Features: For use with most photometric and radiometric detectors supplied by Gigahertz-Optik. Modes: CW, pulse energy from both single and multiple flashes, effective luminous intensity (Blondel-Rey), data logger and others.
P-9801 Eight-channel optometer.

Features: State-of-the-art 8 channel laboratory optometer with a signal amplifier and sample & hold ADC per channel for clocked recording of the measurement signals. RS232 and IEEE488 interface. Trigger input and output.
P-9202-4 Fast response time trans-impedance signal amplifier.

Features: High quality analogue amplifier with current-voltage conversion. Minimal diode offset voltage for short circuit operations. Bandwidths of up to 330kHZ. 1µs rise time. Large I-U amplification range from 10pA/V to 1mA/V.
P-9202-5 Universal trans-impedance signal amplifier.

Features: High quality analogue amplifier with current-voltage conversion. Minimal diode offset voltage (1mV) for short circuit photodiode operations. 5µs to 20ms rise time depending on the amplification. Large I-U amplification range – 1×10-10A/V to 1×10-3 A/V.
P-9202-6 Highly sensitive trans-impedance signal amplifier.

Features: High quality analogue amplifier with current-voltage conversion with minimal diode offset voltage (0.5mV) for short circuit photodiode operation of . 2.5s to 25s rise time depending on the amplification. Large I-U amplification range – 1×10-11A/V to 1×10-4 mA/V.
UMPA-0.5/11 Port adapter for use with UMPF-0.5 port frame of the UM series modular construction integrating spheres.

Features: To attach TD-11, PD-11 or VL-11 detectors and UFC-11 fiber connectors. Optional diffuser window.
UPK-30-L Integrating spheres with precise machined housings.

Features: 1.18 in / 30 mm dia sphere. 5mm dia measurement port. Detector port. 98% synthetic coating.

UPK-30S60-L Integrating spheres with precise machined housings.

Features: 1.18 in / 30 mm dia 60 mm long streched sphere for side emitting fibers. 2mm dia measurement port. Detector port. 98% synthetic coating.

UPK-30S105-L Integrating spheres with precise machined housings.

Features: 1.18 in / 30 mm dia 105 mm long streched sphere for side emitting fibers. 2mm dia measurement port. Detector port. 98% synthetic coating.

UPK-50-L Integrating spheres with precise machined housings.

Features: 2 in / 50 mm dia sphere. 10 mm dia measurement port. Detector port. 98% synthetic coating.

UPK-50-F Integrating spheres with precise machined housings.

Features: 2 in / 50 mm dia sphere. 10 mm dia measurement port. +8 and -8° ports with plugs. Detector port. 98% synthetic coating.

UPK-100-L Integrating spheres with precise machined housings.

Features: 4 in / 100 mm dia sphere. 15 mm dia measurement port. Detector port. 98% synthetic coating.

UPK-100-F Integrating spheres with precise machined housings.

Features: 4 in / 100 mm dia sphere. 15 mm dia measurement port. +8°, -8° and 0° ports with plugs. Detector port. 98% synthetic coating.

Article-Nr Modell Description Request / Compare
Product
100482 PD-1101 (-1 Con.)

Detector without Calibration

100483 PD-1101 (-2 Con.)

Detector without Calibration

100484 PD-1101 (-4 Con.)

Detector without Calibration

100811 PD-1102 (-1 Con.)

Detector without Calibration

15296996 PD-1102 (-2 Con.)

Detector without Calibration

15296997 PD-1102 (-4 Con.)

Detector without Calibration

100845 PD-1103 (-1 Con.)

Detector without Calibration

15296998 PD-1103 (-2 Con.)

Detector without Calibration

15296999 PD-1103 (-4 Con.)

Detector without Calibration

100846 PD-1104 (-1 Con.)

Detector without Calibration

15297000 PD-1104 (-2 Con.)

Detector without Calibration

15297001 PD-1104 (-4 Con.)

Detector without Calibration

101275 PD-1105 (-1 Con.)

Detector without Calibration

15297002 PD-1105 (-2 Con.)

Detector without Calibration

15297003 PD-1105 (-4 Con.)

Detector without Calibration

PD-1106 (-1 Con.)

Detector without Calibration (Discontinued)

PD-1106 (-2 Con.)

Detector without Calibration (Discontinued)

PD-1106 (-4 Con.)

Detector without Calibration (Discontinued)

PD-1107 (-1 Con.)

Detector without Calibration (Dicsontinued)

PD-1107 (-2 Con.)

Detector without Calibration (Discontinued)

PD-1107 (-4 Con.)

Detector without Calibration (Discontinued)

PD-1108 (-1 Con.)

Detector without Calibration (Discontinued)

PD-1108 (-2 Con.)

Detector without Calibration (Discontinued)

PD-1108 (-4 Con.)

Detector without Calibration (Discontinued)

101172 PD-1109 (-1 Con.)

Detector without Calibration

15297010 PD-1109 (-2 Con.)

Detector without Calibration

15297011 PD-1109 (-4 Con.)

Detector without Calibration

15297355 PD-1112 (-1 Con.)

Detector without Calibration

15297356 PD-1112 (-2 Con.)

Detector without Calibration

15297357 PD-1112 (-4 Con.)

Detector without Calibration

15308939 PD-1115 (-1 Con.)

Detector without calibration

15308940 PD-1115 (-2 Con.)

Detector without calibration

15308941 PD-1115 (-4 Con.)

Detector without calibration

Calibration
15299990 KDW-S1-02

Calibration of the spectral responsivity in A/W from 250 to 1100nm or spectral responsivity range of detector in calibration (min. sensing area size is required)

15300584 KDW-S1-03

Calibration of the spectral responsivity in A/W from 800 to 1800nm (min. sensing area size is required)

Product tags