This Product is discontinued, please contact us if you are still interested. An alternative is e.g:

The P-9802 is designed as optometer with up to 36 channels for use under remote control operation.

Multi Channel Lightmeter for Long Term Burn-in 

Typical applications for the P-9802 are burn-in and life time measurements but also light distribution measurement applications.


Metal housing for use in strong ambient electromagnetic environments 

For integration of the P-9802 in applications in strong ambient electromagnetic environments, e.g. high power arc lamp measurement, the P-9802s offer a high quality metal housing for best EMV shielding and rack mount option.


Extendable Electronic Design from two to thirty six Channels 

The P-9802 electronics design is based on a master board with an external RS232 interface and an internal I2C bus to control up to 18 amplifier modules P-9802Z-1.The number of modules is order specific allowing the meter to be configured to individual needs. The basic version of the P-9802 has one amplifier module with two signal inputs. Additional amplifier modules allow the optometer to be expanded up to a maximum of 18 amplifier modules. Each module implements a signal amplifier with two switchable signal inputs.


Wide selection of Light Detector for Photometric and Radiometric Measurements 

The flexibility to combine the P-9802 with most Gigahertz-Optik detector heads enables it’s use in a wide application range of radiometric and photometric measurements. The detector heads are connected via BNC sockets located on the front and back panels of the instrument. 


Measurement Range Specifications with Light Detectors

The measurement range of optometer combined with light detector is calculated by the measurement range specification of the optometer and the responsivity of the detector head as follows:

    • Offset signal = Maximum Resolution = meter current offset signal / detector sensitivity
      Sample: 0.1pA (0.1E-12 A) / 3 nA/(mW/cm²) (irradiance detector) = 0.33 nW/cm²

 

    • Minimum measureable irradiation = offset signal * signal to noise ratio factor
      Sample: 0.33 nW/cm² * 50 = 17 nW/cm²

 

    • Maximum measureable irradiation*: max. signal current detector / detector sensitivity
      Sample: 200 µA (200E-6 A) / 3 nA/(mW/cm²) = 66667 W/cm²

 

    • Display range = Offset signal to maximum measureable signal
      Sample: 0.33 nW/cm² to 66667 W/cm²

 

    • Measurement range: = min measureable irradiation to maximum measureable irradiation
      Sample: 17 nW/cm² to 66667 W/cm²


*) The maximum measureable irradiation value may also be limited by thermal radiation, intense UV radiation or other application dependent parameters which must be considered by the end-user.

P-9802
Product
Detector interface

BNC type connector

Measurement range

7, fixed selection or automatically (for specification see table below)

CW integration time

20 ms to 4 s (set by RS232 command)

Measurement modes

CW, Peak, Dose, Relative (%), channel A / channel B (%)

dose measurement

Integration of the measured values at 1s/100ms intervals

Offset

offset compensation in all ranges

Calibration

storage from up to 255 data sets

Interface

only via RS232

Interface

RS232 (9600 baud, 8 digit, 1 stop bit, no parity)

Measurement range

7 (0.200 mA to 0.1 pA) manual or autorange

Range
(A/V)
Range
max.
Slew-Rate
(10% - 90%)
Uncertainty*) (with offset compensation)
1 year, 23 °C ± 5 °C
± (% of reading + % of range)
1x10-4 200.0 µA 30 ms 0.2 % + 0.05 %
1x10-5 20.00 µA 30 ms 0.2 % + 0.05 %
1x10-6 2.000 µA 30 ms 0.2 % + 0.05 %
1x10-7 200.0 nA 30 ms 0.2 % + 0.05 %
1x10-8 20.00 nA 30 ms 0.2 % + 0.05 %
1x10-9 2.000 nA 30 ms 0.2 % + 0.05 %
1x10-10 200.0 pA 30 ms 0.2 % + 0.05 %

*) Current calibration of each range by use of a precise current source with DAkks calibration

Interface
DSUB 9pin female Function
2 TxD
3 RxD
5 GND
1-4-6 connected
7-8 connected

The parameters of the RS232 interface are fixed and can not be modified.

Miscellaneous
Power Supply

with supplied external mains supply

temperature range

5 °C - 40 °C

compatible

compatible

Warranty

12 month

Type Description File-Type Download
Datasheet P-9802 PDF
Produktname Product Image Description Show product
VL-3701 Detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 3 %, f2 ≤ 1.5 %, 0.5 nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

VL-3702 Detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 6 %, f2 ≤ 3 %, 0.5 nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

VL-3704 Detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 5 %, f2 ≤ 3 %, 20pA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

VL-3705 Detector head for the measurement of scotopic illuminance in Lux [lx].

Features: f1 ≤ 5 %, f2 ≤ 3 %, 0.2nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

PD-9310A High sensitive detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 3 %, 2.8nA/lx, 20mm diffuser, for the usage with optometers and amplifiers, calibration certificate

PD-9310B High sensitive detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 6 %, 2.8nA/lx, 20mm diffuser, for the usage with optometers and amplifiers, calibration

PD-9310B-N Very high sensitive detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 3 %, 28nA/lx, no diffuser, for the usage with optometers and amplifiers, calibration

VL-1101 + UMPA-0.5-11-RD Detector head Module detector head for the measurement of photopic illuminance in Lux [lx].

Features: UMPA adapter for usage with integrating spheres, for the usage with optometers and amplifiers, calibration certificate

LDM-9810 Detector head to measure the photopic spot luminance in cd/m².

Features: selectable 20', 1° and 6° viewing angles, view finder, focus able achromatic lens, for the usage with Optometers and amplifiers, calibration certificate.

LDM-9901 Detector head to measure the photopic spot luminance in cd/m².

Features: 1.1° viewing angle, simple to use, very low stray light, for the usage with Optometers and amplifiers, calibration certificate.

VL-1101 Photometric detector head with VL-11 mount.

Features: modular detector for use with integrating spheres, front lenses etc. For use with optometers and signal amplifiers

ISD-5-VL Integrating sphere detector for luminous flux (lm) of 2π spot sources.

Features: 50mm dia, BaSO4 coating, 12.5mm dia port, for the usage with optometers and signal amplifiers, Calibration certificate

ISD-10-VL Integrating sphere detector for luminous flux (lm) of 2π spot sources.

Features: 100 mm dia, BaSO4 coating, 15 mm dia port, for the usage with optometers and signal amplifiers, Calibration certificate

TD-11VL01 Photometric, temperature stabilized detector with DP-11 mount.

Features: for use with integrating spheres, Operation temperature 50 °C, for use with optometers and signal amplifiers

PD-9304 Universal detector head for LASER power, illuminance and 400-1100 nm iiradiance.

Features: Si-photodiode with 1 cm², exchange able filters and cosine diffuor, for the usage with optometers and signal amplifiers

RW-3701 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 400-500nm (BLUE), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3702 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 700-800nm (RED), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3703 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 400-800nm (VIS), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3704 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 800-1000nm (NIR), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
RW-3705 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 400-1000nm (VISNIR), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3708 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 950-1700nm (NIR), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3701 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 315-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
UV-3702 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 280-315nm (UV-B), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3703 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 200/250-280nm (UV-C), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3710 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 320-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
UV-3711 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 280-320nm (UV-B), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3716 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 305-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
UV-3717 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 315-400nm (UV-A), low cross talk from radiation > 400 nm, cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3719 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 250-400nm (UV), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3720 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 240-320nm (UV), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3718 Detector head for the measurement of high irradiance of UV-C 254nm radiation in W/m².

Features: pre-aging for long time stability, cosine field-of-view, metal shielded cable, for the usage with optometers and amplifiers, calibration certificate.

RCH-102 Detector head for high intensity irradiation in UV or blue light curing processes.

Features: Separate light integrator and detector with rigid fiber coupling, (320-460)nm UVABLUE responsivity, wide viewing angle, for the usage with optometers and amplifiers, calibration certificate.
LP-9901 Detector head to measure LASER radiant power in W and LASER irradiance in W/m².

Features: Low height detector with 7mm dia active area, 400 to 1100nm, for the usage with optometers and signal amplifiers, calibration certificate.

ISD-3P-Si Integrating sphere detector for Laser power in W.

Features: 30 mm dia, 5 mm dia port, synthetic ODM98 coating, 400 nm - 1100 nm responsivity, for the usage with optometers and signal amplifiers, Calibration certificate

ISD-5-Si Integrating sphere detector for Laser power in W.

Features: 50 mm dia, 12.5 mm dia port, BaSO4 coating, 400 nm - 1100 nm responsivity, for the usage with optometers and signal amplifiers, Calibration certificate

ISD-5P-Si Integrating sphere detector for Laser power in W.

Features: 50 mm dia, 10 mm dia port, synthetic ODM98 coating, 400 nm - 1100 nm responsivity, for the usage with optometers and signal amplifiers, Calibration certificate

ISD-10-Si Integrating sphere detector for Laser power in W.

Features: 100mm dia, 15mm dia port, BaSO4 coating, 400-1100nm responsivity, for the usage with optometers and signal amplifiers, Calibration certificate

PD-11 series Detector head with DP-11 mount.

Features: modular detector for use with integrating spheres, front lenses etc, Si, SiLP, InGaAs, SiC, GaP photodiodes, for use with optometers and signal amplifiers

UV-3706 Detector head to measure irradiance W/m2 in Bilirubin phototherapy.

Features: Bilirubin actinic responsivity, cosine field-of-view, for usewith optometers, calibration certificate.

UV-3711-308 Detector head for the measurement of irradiance of 308nm Eximer Lasers in W/m².

Features: flat spectral responsivity besite 308nm. cosine field-of-view, dose measurement in conjuntion with P-9710-2 optometer, calibration certificate

UV-3709 Detector for Blue-light hazard measurements.

Features: Single-cell detector, BLH actinic irradiance, for the use with optometer, calibration certificate

UV-3725 Detector for the measurement of UV-C 254 nm irradiance in air disinfection applications.

Features: wide dynamic range for UV hazard and effective irradiance, wide angle cosine F.O.V. for straylight measurements, for the usage with optometers, calibration certificate.
PS-3701 Detector head for plant growth.

Features: 400-700nm PAR actinic irradiance, cosine field-of-view, for use with optometers, calibration certificate.

PS-3702 Detector head for plant growth.

Features: 320-500nm phototropism actinic irradiance, for use with optometers, calibration certificate.

PS-3703 Detector head for plant growth.

Features: 590-900nm photomorphogenesis actinic irradiance, for use with optometers, calibration certificate.

PRW-0505 Integrating sphere detector for radiant power in W of 2π spot sources.

Features: 400 - 1100 nm radiometric responsivity, 50 mm dia integrating sphere, 12.5 mm dia measurement port, for the usage with optometers and signal amplifiers, Calibration certificate
ISD-3P-IGA Integrating sphere detector with InGaAs photodiode and 30 mm sphere for Laser power in W.

Features: 800 nm - 1800 nm spectral responsivity, 5 mm dia measurement port, synthetic ODM98 coating, optional SMA Adapter, for the usage with Optometer and signal amplifiers, calibration certificate
ISD-5P-SiUV Integrating sphere detector with UV-enhanced Si photodiode and 50 mm sphere for Laser power in W

Features: 250 nm - 1100 nm spectral responsivity, 10 mm dia measurement port, synthetic ODM98 coating, optional SMA Adapter, for the usage with Optometer and signal amplifiers, calibration certificate

ISD-5P-IGA Integrating sphere detector with InGaAs photodiode and 50 mm sphere for Laser power in W.

Features: 800 nm - 1800 nm spectral responsivity, 10 mm dia measurement port, synthetic ODM98 coating, optional SMA Adapter, for the usage with Optometer and signal amplifiers, calibration certificate

Article-Nr Modell Description Request / Compare
Product
15295274 P-9802

Meter, with power supply and manual

Accessories
15295276 P-9802Z-1

Amplifier board

Product tags


Similar products