Uniform light sources with continous emission spectrum

Tungsten halogen lamp based uniform light sources.


Tungsten halogen lamp based uniform light sources with manual and remote control variable intensity.  Monitor detectors. Integrating sphere diameters from 50mm to 1000mm.

Integrating sphere light sources with continuous emission spectrum.
Model Image Sphere Diameter Light output port Calibrated spectral range / nm Light source Output range Output adjustment Monitor detector Remark
ISS-5P ISS 5P 50 mm

20 mm

(380 - 1100) nm Integrated 10 W tungsten-halogen None - Compact and portable transfer standard lamp
ISS-5P-SR-FS ISS 5P 50 mm

20 mm

(380 - 1700) nm LH-5-UV-Quartz halogen None - e.g. for fluorescence spectrometer calibration
ISS-8P-HP ISS 8P HP 80 mm

19 mm

(380 - 1100) nm External up to 100W tungsten-halogen (120, 12 & 1.2) kcd/m² @ CCT 2960K (75, 75, 0.75) kcd/m² @ CCT 2856K Exchangeable OD0, OD1 & ODx filters - Constant color temperature and uniformity as luminance varied.
ISS-8P-VA ISS 8P VA 80 mm

19 mm

(380 - 1100) nm External up to 100W tungsten-halogen (0 - 95000) cd/m² @ CCT 2960K (0 - 63000) cd/m² @ CCT 2856K Manual control variable aperture - Continually variable intensity control.
ISS-8P-VAHP ISS 8P VAHP 80 mm

19 mm

(380 - 1100) nm External up to 100W tungsten-halogen (0 - 57000) cd/m² @ CCT 2960K (0 - 39000) cd/m² @ CCT 2856K Exchangeable OD0, OD1 & OD filters + variable aperture - Fine adjustment, continually variable intensity control.
ISS-17-VA ISS 17 V2.77 170 mm

50 mm with resolution tube to suppress the lateral incident light (UMPA-2.0-xx)

(380 - 800) nm External 100W tungsten-halogen (3 - 7.500) cd/m² @ CCT 2856K (5 - 15.000) cd/m² @ CCT 3100K Manual control variable aperture CT-4501-4 Monitor detector calibrated for color temperature and luminance
ISS-17-VAM ISS 17 V2.77 170 mm

50 mm with resolution tube to suppress the lateral incident light (UMPA-2.0-xx)

(380 - 800) nm External 100W tungsten-halogen (3 - 7.500) cd/m² @ CCT 2856K (5 - 15.000) cd/m² @ CCT 3100K Motorised variable aperture CT-4501-4 Monitor detector calibrated for color temperature and luminance
ISS-30-VA ISS 30 VA V01 webheader 300 mm

100 mm

(300 - 1100) nm @ CCT 2960K External 100W tungsten-halogen (0 - 3500) cd/m² @ CCT 2960K Manual control variable aperture Photometric detector Monitor detector calibrated for output port luminance
ISS-30-VAM ISS 30 VA V01 webheader 300 mm

100 mm

(300 - 1100) nm @ CCT 2960K External 100W tungsten-halogen (0 - 3500) cd/m² @ CCT 2960K Motorised variable aperture Photometric detector Monitor detector calibrated for output port luminance
ISS-50-LU-FE ISS 50 FRP005 1 webheader 500 mm - 3 x 100W tungsten-halogen each 2856K, 5000K or 6000K, filter wheel selected - - - Hemispheric illuminated field due to position of super wide-angle or fish-eye cameras in the sphere center. Three different color temperatures, switchable with filter wheels.