Light meters for radiometry

Radiometers for the measurement of UV-visible-NIR irradiance (W/m²) and radiant flux (W).


Radiometers for measuring irradiance within the spectral range 250 nm to 1700 nm.

Radiometers for UV-Vis-NIR irradiance (W/m²)
Model Image Usage Spectral function Wavelength range / nm Typ. Range Minimum SNR=50 100ms integration Typ. Range Maximum Cosine diffuser Measurement mode Interface Remark

X1 + UV-3710

X1 1+VL 3701 4.26 Mobile UV-A 320 - 400 nm 0.7 mW/m² 14 kW/m² 11 mm Ø CW USB

P-9710 + UV-3701

P 9710+RW 3705.23 Mobile / Benchtop UV-A 315 - 400 nm 1.3 mW/m² 25 kW/m² 11 mm Ø CW, Flash, Dose, Logger RS232

P-9710 + UV-3702

P 9710+RW 3705.23 Mobile / Benchtop UV-B 280 - 315 nm 3 mW/m² 29 kW/m² 11 mm Ø CW, Flash, Dose, Logger RS232

P-9710 + UV-3703

P 9710+RW 3705.23 Mobile / Benchtop UV-C 250 - 280 nm 2.5 mW/m² 25 kW/m² 11 mm Ø CW, Flash, Dose, Logger RS232

X1 + UV-3718

X1 1+VL 3701 5.26 Mobile Narrowband UV-C 254 nm 2.5 mW/m² 25 kW/m² 11 mm Ø CW USB

X1 + UV-3719

X1 1+VL 3701 5.26 Mobile Broadband UV 250 - 400 nm 2.6 mW/m² 52 kW/m² 11 mm Ø CW USB

P-9710 + UV-3725

P 9710+RW 3705.23 Mobile / Benchtop UV-GI 254 nm 2.5 mW/m² 25 kW/m² 11 mm Ø CW, Flash, Dose, Logger RS232

X1 + RW-3703

X1 1+VL 3702.24 Mobile Visible 400 - 800 nm 3.3 mW/m² 667 kW/m² 11 mm Ø CW USB

P-9710 + RW-3705

P 9710+RW 3705.23 Mobile / Benchtop Vis-NIR 400 - 1000nm 0.5 mW/m² 100 kW/m² 11 mm Ø CW, Flash, Dose, Logger RS232

P-9801 + RW-3703

p9801 Benchtop Visible 400 - 800 nm 3.3 mW/m² 667 kW/m² 11 mm Ø CW, Flash, Dose, Logger, Ratio, Trigger RS232 / IEEE-488

P-9801 + RW-3704

p9801 1 Benchtop NIR 800 - 1000 nm 0.13 mW/m² 25 kW/m² 11 mm Ø CW, Flash, Dose, Logger, Ratio, Trigger RS232 / IEEE-488

P-9801 + RW-3708

p9801 1 Benchtop Extended NIR 950 - 1700 nm 0.13 mW/m² 25 kW/m² 11 mm Ø CW, Flash, Dose, Logger, Ratio, Trigger RS232 / IEEE-488

 

 

Radiometers for measuring visible and NIR  (to 1700 nm) radiant flux (W).

Radiometers for Vis-NIR radiant flux (W)
Model Photo Usage Wavelength range / nm Typ. Range Minimum SNR=50 100ms integration Typ. Range Maximum Entrance optic Measurement mode Interface Remark

P-9710 + ISD-5-VISNIR

P 9710 2+ISD 5P Si.21 Mobile / Benchtop 400 -1100nm 4.4 nW 800 mW (*1) Sphere 50 mm Ø port 12.7 mm Ø CW, Flash, Dose, Logger RS232

X1 + ISD-5-VISNIR

isd5l Mobile 400 -1100nm 4.4 nW 800 mW (*1) Sphere 50 mm Ø port 12.7 mm Ø CW USB

X1 + ISD-3P-Si

isd3p Mobile 400 -1100nm 7.8nW @630nm 5.6nW @900nm 1.56W @630nm 1.13W @900nm Sphere 30mmØ port 5mmØ CW USB

X1 + ISD-3P-IGA

isd3p Mobile 800-1800 nm 0.29µW @1300nm 0.25µW @1550nm 5.9W @1300nm 5.0W @1550nm Sphere 30mmØ port 5mmØ CW USB

X1 + ISD-5P-Si

isd5l Mobile 400-1100nm 2.0 nW @630nm 400 mW @630nm Sphere 50 mmØ port 10 mmØ CW USB

X1 + ISD-5P-IGA

isd5l Mobile 800-1800 nm Sphere 50 mmØ port 10 mmØ CW USB

PLL-1701 + ISD-3P-IGA

PLL 1701jpg Mobile / Benchtop 800-1800 nm Sphere 30mmØ port 5mmØ USB / Analogue

P-9710-2 + ISD-5P-Si

P 9710 2+ISD 5P Si.21 Mobile / Benchtop 400-1100nm 2.0 nW @630nm 400 mW @630nm Sphere 50 mmØ port 10 mmØ CW, Flash, Dose, Logger RS232

P-9710-2 + ISD-5P-IGA

P 9710 2+ISD 5P Si.21 Mobile / Benchtop 800-1800 nm Sphere 50 mmØ port 10 mmØ CW, Flash, Dose, Logger RS232

P-9710-2 + ISD-10-Si

isd10s Mobile / Benchtop 400-1100nm 3.1nW @630nm 2.6nW @900nm 0.6W @630nm 0.5W @900nm Sphere 100mmØ port 15mmØ CW, Flash, Dose, Logger RS232

P-9710-2 + ISD-15-Si

isd15si Bench top 400 -1100nm 83nW @630nm 71nW @900nm 16W @630nm 14W @900nm Sphere 150 mmØ port 38.1 mmØ CW, Flash, Dose, Logger RS232

P-9710-2 + ISD-30-Si

isd30 si Bench top 400-1100nm 25nW @630nm 20nW @900nm 5W @630nm 4W @900nm Sphere 300mmØ port 100mmØ CW, Flash, Dose, Logger RS232

P-2000-2 + ISD-30-SiIGA

isd30 si Bench top 400 -1800 nm 25nW @630nm 20nW @900nm 200nW @1300nm 280nW @1550nm 4W @630nm 5W @900nm 40W @1300nm 55W @1550nm Sphere 300mmØ port 100mmØ CW, Flash, Dose, Logger RS232 / IEEE488

P-9710-4 + ISD-1.6-SP-Vxx

ISD 1.6 xx.51 Mobile 400-1100nm 0.73µW @630nm 0.66µW @900nm 14.6W @630nm 13.3W @900nm Sphere 16mmØ port 5mmØ Pulse energy, pulse shape RS232 Optional oscilloscope for pulse shape

(*1) Max CW flux may be limited by max. operation temperature

See also:  Integrating sphere based spectroradiometer systems