This Product is discontinued, please contact us if you are still interested. An alternative is e.g:

Ultraviolet radiation is used in the treatment of certain skin diseases like Psoriasis and for photobiological studies like SPF testing. Measuring the source irradiance or energy is required for accurate dosimetry and safety purposes. Typical wavelength ranges of interest are UV-A: 320nm - 400 nm, UV-B: 280 nm - 320 nm and UV-B: 311 nm. The two cell XD-9501 detector includes filtered detectors for both the UV-A and UV-B spectral ranges and a cosine corrected field of view.

Traceable calibration

Calibration of the detector UV-A and UV-B (W/m²) responsivity is performed by the Gigahertz-Optik GmbH calibration laboratory for optical radiation measurements quantities. As with all light detectors supplied by Gigahertz-Optik calibration of absolute detector responsivity as well as detector individual measured relative spectral responsivity data is included.

Recommended Optometer

X11, X12

XD-9501 Typical Spectral Response
Specification
spectral responsivity

Ch 1: UV-A 315 nm - 400 nm
Ch 2: UV-B 280 nm - 315 nm

 

typical responsivity

17 nA/(W/m²)
2.5 nA/(W/m²)

Max. signal current

100 µA
50 µA

Input optics

8 mm Ø Diffuser

Miscellaneous
temperature range

(5 - 40) °C

Cable Length

2 m

Plug Types

-4

Type Description File-Type Download
Datasheet XD-9501 PDF
Produktname Product Image Description Show product
X1 Four-channel USB optometer designed for mobile use.

Features: Compact device for use with all photometric, radiometric, colorimetric, plant-physiologic and photo-biologic measurement heads from Gigahertz-Optik. USB interface. Battery operation or power supply USB.
X1-RM Optometer in 3HE housing for use in 19” racks.

Features: Its USB and RS232 remote interface and two additional RS232 device interfaces make the device highly flexible when it comes to system integration. Its four signal inputs enable use with all photometric, radiometric, colorimetric, plant-physiologic and photo-biologic measurement heads from Gigahertz-Optik.
X1-PCBC Optometer module.

Feature: The X1 optometer is available as a printed circuit board either with or without a housing and is suited for applications that do not require a keyboard or display. Four signal inputs enable connection with all measuring heads from Gigahertz-Optik.
X1-PCB Optometer module.

Feature: The X1 optometer is available as a printed circuit board either with or without a housing and is suited for applications that do not require a keyboard or display. Four signal inputs enable connection with all measuring heads from Gigahertz-Optik.
Article-Nr Modell Description Request / Compare
Product
15295881 XD-9501 (-4 Connector)

Detector, Calibration Certificate

15300111 K-XD9501-I

Recalibration with Calibration Certificate

Calibration
15300493 K-FOV-02

Measurement of two-cell UV Irradiance detectors cosine field of view function

Re-calibration
15300571 K-UV-SR

Calibration of relative spectral responsivity from 250 nm to 550 nm