Irradiance Detectors with Radiance Attachment

A cost effective strategy to perform both irradiance and radiance measurements is to outfit RW-37 and UV-37 series irradiance detectors with front lens adapters. The radiance adapters limit the field of view of the irradiance detector to enable radiance measurement in W/(m²sr) of larger area radiance sources.


Simple Assembly

The SRT-M37L series front lenses attach to the front of the 37-type type detector housings using the SRT-M45/37 base mount which fits onto the detector housing and is held in place with set screws. The SRT-M45/37B is internally threaded (M37x1) so that the externally threaded SRT-M37L front lens can be screwed into it. The SRT-M45/37B base mount has an M6 and standard camera (1/4”-20 BSW) threaded hole for tripod or bench post or to fixture the device into an application.


1° to 10° Selectable Field-of-Views

Front lenses with 1°, 2°, 5° and 10° are available.


Traceable Calibrations

Lens and detector assembly is calibrated in radiance sensitivity in W/m²sr at Gigahertz-Optik’s Calibration Laboratory for Optical Radiation Quantities.

SRT-M45/37-B Adapter
Specification
SRT-M37L-1

Front lens glass with 1° field of view. Needs SRT-M45/37B to couple with RW-37 type detector. 0.7 mm diameter hole aperture

SRT-M37L-2

Front lens glass with 2° field of view. Needs SRT-M45/37B to couple with RW-37 type detector. 1.4 mm diameter hole aperture.

SRT-M37L-5

Front lens glass with 5° field of view. Needs SRT-M45/37B to couple with RW-37 type detector. 3.4 mm diameter hole aperture

SRT-M37L-10

Front lens glass with 10° field of view. Needs SRT-M45/37B to couple with RW-37 type detector. 7 mm diameter hole aperture

Type Description File-Type Download
Datasheet RW-37 with SRT-M37-L PDF
Produktname Product Image Description Show product
P-9710 High-quality device for measurement of CW-, single pulse and modulated radiation.

Features: Optometer for all detector heads with calibration data plug. Measurement modes: CW, pulse energy, dose, peak-to-peak, effective luminous intensity (Blondel-Rey), data logger, battery, main power, RS232
X1 Four-channel USB optometer designed for mobile use.

Features: Compact device for use with all photometric, radiometric, colorimetric, plant-physiologic and photo-biologic measurement heads from Gigahertz-Optik. USB interface. Battery operation or power supply USB.
P-2000 Two-channel optometer.

Features: For use with most photometric and radiometric detectors supplied by Gigahertz-Optik. Modes: CW, pulse energy from both single and multiple flashes, effective luminous intensity (Blondel-Rey), data logger and others.
P-9801 Eight-channel optometer.

Features: State-of-the-art 8 channel laboratory optometer with a signal amplifier and sample & hold ADC per channel for clocked recording of the measurement signals. RS232 and IEEE488 interface. Trigger input and output.
Article-Nr Modell Description Request / Compare
Product
15295665 SRT-M37L-1

1° Front Lens

15295666 SRT-M37L-2

2° Front Lens

15295668 SRT-M37L-5

5° Front Lens

15295740 SRT-M37L-10

10° Front Lens

Calibration
15300580 K-Si-SR

Calibration of relative spectral responsivity from 250 nm - 1100 nm or the detectors spectral responsivity range

15300571 K-UV-SR

Calibration of relative spectral responsivity from 250 nm - 550 nm or the detectors spectral responsivity range

15300581 K-NIR-SR

Calibration of relative spectral responsivity from 800 nm - 1800 nm or the detectors spectral responsivity range

Accessories
*) PMS-

Post-Mount Stand components, see PMS products.