This Product is discontinued, please contact us if you are still interested. An alternative is e.g:

Light transmission

Light transmission is the visually sensed light permeability of materials. It is particularly important when it comes to specification of window panes on all types of vehicles, display sheets and disks as well as all the other samples whose transmission is assessed with the photometric responsivity (V(λ)) of the human eye.


Light transmission measurement

Light transmission is a relative measurand. It describes the signal difference of the measured luminance in a geometrically defined radiation beam path. The measurements are done both without a test sample (100%) and with a test sample. The light source of the measurement device must be characterized by a spectrum that corresponds to the standard illuminant type A, C or D50. The spectral responsivity of the receiver must match that of the human eye. These properties allow ECE R43 conform measurements.


LCRT-2005-S light transmission measurement device

The LCRT-2005-S is elaborately designed for light transmission measurement of thin, scratched and clear samples. The D/O measurement geometry comprises of an integrating sphere light source and a luminance measurement device. The monitor detector of the light source and that of the receiver are equipped with a diode array. The spectral measurement data enables precise simulation of the standard light spectra and the photometric responsivity spectrum of the receiver. The sample is aligned in front of the light source for measurement. The degree of light transmission can thus be determined through diffuse sample illumination for thin scratched samples as well.


LCRT-2005-S spectrophotometer

The LCRT-2005-S can also be used as a spectrophotometer due to its spectral measurement detectors in source and receiver. The spectral range is between 425 and 705nm.


Measurement device for freehand measurements

The integrating sphere light source is well guarded against shock and stains by its synthetic coating, LED lamps and the protective glass on the illumination field. In order to minimize any effects by ambient light, the measurement is performed using pulsed light. The device is also equipped with a camera to aid in alignment of the source and receiver for freehand measurements. The device can be powered using four AA batteries or via USB. A hard-top casing is also supplied for safe storage and transport of the device as well as its spare batteries and accessories.


Fast and simple freehand measurements

One of the characteristic properties of the LCRT-2005-S is its ability to easily perform a quick measurement in only a couple of minutes:

1) Connection of the source and receiver to the controller device
2) 100% adjustment measurement
3) Alignment to the test sample
4) Automatic start of the measurement
5) Display of the measurement values


USB interface with readout software

The USB interface enables data readout and power supply. The software delivered with the device can be used for measurement data readout.


Traceable measurements

Two transmission standards with 70% and 80% light transmittance are offered for device matching in applications where traceable measurement values are required.

Measurement geometry: 100% setup
Measurement geometry for thin, non-scattering samples
Measurement geometry for thin, scattering samples
Freehand light transmission measurement: 1) 100% adjustment 2) sample alignment (DUT) 3) automatic measurement start upon setup, 4) Display of the measurement values
General
Short description

Mobile measuring Instrument for light transmission.

Main features

Spectral measuring method. Compact source and receiver. Build in camera for receiver to source alignment support. Controller with battery (four AA) or USB power operation. Puls modulated LED lamp for measurements in ambient light conditions. 

Measurement range

Spectral range: 425 nm to 705 nm

Spectral resolution: 5 nm

Transmission range: 5 % to 100 %

Measurement beam diameter: 6.6 mm 

Illumination: A, C, D65

Detection: Spectral Photometric, Spectral Radiometric

typical applications

Measurement of the light lransmission of automotive and all other vehicles front and side windows. Measurement of the spectral transmission of thin films and thin plates. 

Calibration

Realative measurement methode with 100 % reference adjustment.

Optional calibration with 70 % or 80 % calibration standards.   

Product
Measurement geometry

D/0 geometry; measurement of the luminance ratio with a diffuse light source as per CIE 130 & DIN 5036.

Beam diameter

6.6 mm at contact measurement

Light Source

Integrating sphere light source with a 20 mm illumination field; LED lamps; diode array monitor detector.

Simulation of the standard illuminants type A, D65 and D50.

Sensor

Diode array detector with radiance lens. Depolarizer for measurement of polarized samples. Simulation of photometric responsivity. Digital camera for aid in freehand setup of source and receiver.

spectral range

425 nm to 705 nm

Measurement range

5 % to 100 % transmission for a color-neutral transmission spectrum

typical Measurement uncertainty

± 1 % absolute

Data Resolution

0.1 %

Calibration

Relative measurements after performing 100% match against air.
Traceable measurements after matching with calibrated standard filters.

Source
Light Source

White LEDs in pulse mode, usable wavelength range: 425 nm to 705 nm

Monitor detector

array spectrometer based on a 256 pixel diode

Connector

Length 1.5m

Mini DIN plug

RS232 and voltage supply

Housing

Aluminium profile with plastic caps

Threaded bores for mounting

Dimensions

160 mm x 45 (60) mm x 85 mm

Weight

450 g

Light Source

Integrating sphere with synthetic ODM98 coating. 20 mm illumination field diameter with homogenous luminance distribution (lambertian radiator). Illumination field equipped with a protective shield.

Receiver
Sensor

256 pixel diode array spectrometer with an achromatically corrected lens. Implemented depolarizer for measurement of polarized samples.

Measurement beam geometry

Measurement field angle - 0.38 °

Sample alignment 0 °

illumination field diameter by contact measurement - 6.6 mm, in 1 m measurement distance 12.6 mm

Dimensions

160 mm x 45 mm x 85 mm

Weight

400 g

Controller
Source and receiver connector

Two mini DIN plug connections

Display

Monochromatic display with backlight that can be switched on/off

Parameter adjustment

Menu operated

saving of the last used settings

four control buttons

Interface

USB

Power Supply

4 x AA batteries

alternative 4 x AA batteries with external charger

USB

Dimensions

230 mm x 72 (115) mm x 35 (50) mm

Weight

400 g

Miscellaneous
temperature range

10 °C to 40 °C

Humidity

Above the saturation temperature

Type Description File-Type Download
Datasheet LCRT-2005-S PDF
Produktname Product Image Description Show product
B2S-40-TRTH Rail-bench to extend the LCRT-2005-S use to evaluate thin samples transmission by diffuse and regular illumination.

Features: stable 1m length rail bench with stand for source and receiver. Carriage with sample holder.
PMS-RIT Stand to extend the LCRT-2005-S use to measure the regular (in-line) transmission of thick samples up to 100mm thickness.

Features: stable stand with mount for source and receiver. Sample table.

Article-Nr Modell Description Request / Compare
Product
15296702 LCRT-2005-S

Measurement device, 100% adjustment support plate, setup aid, hard case, software CD, handbook

Accessories
15297874 LCRT-2005-S-BN-T70

Spectral calibration standard with 70% light transmission; calibration certificate

15297875 LCRT-2005-S-BN-T80

Spectral calibration standard with 80% light transmission; calibration certificate

15305907 LCRT-2005-S-BN-T100

100% alignment plate

15298554 LCRT-2005-S-Z01

Bench-top stand for source and receiver

15298640 B2S-40-TRTH

Optical bench with adjustable sample holder

15297916 PMS-RIT

Bench-top stand for source and receiver

Product tags


Similar products