This Product is discontinued, please contact us if you are still interested. An alternative is e.g:

Integrating Sphere Detector

The ISD-3P-Si integrating sphere detector employ a 30 mm diameter ODM98 coated integrating sphere with 5mm diameter measurement port. The unique collar baffle limits direct irradiation of the detector from dispersed light. The collar baffle enables optional detector ports to be added for additional detectors, fiber connectors or auxiliary use. The ISD-3P-Si features a Si photodiode detector for use in the spectral range from 400 to 1100nm spectral range. 

Synthetic Coating 

Gigahertz-Optik’s synthetic ODM98 coating offers almost perfect hemispherical diffuse reflection for best light distribution inside the sphere. 

Traceable Calibrations 

Calibration of spectral radiant power sensitivity in W is performed in 10 nm steps from 400 to 1100 nm at Gigahertz-Optik’s Calibration Laboratory for Optical Radiation Quantities.

Typical Spectral Responsivity
Calibration
Calibration

Calibration of spectral radiant power responsivity in A/W in 10nm steps from 400 nm - 1100 nm

Specification
typical responsivity

400 nm - 1100 nm radiometric

typical responsivity

6.41E-04 A/W @ 630 nm

8.87E-04 A/W @ 900 nm

max. Radiant Power (Peak)

312 mW @ 633 nm & 2 00µA

225 mW @ 900 nm & 2 00µA

1559 mW @ 633 nm & 1 mA

1127 mW @ 900 nm & 1 mA

max. Radiant Power (CW)

may be limited by max. operation temperature

Max. signal current

1 mA

Input optics

5 mm Ø

Sphere diameter

30 mm

Coating

synthetic ODM98

Sensor

Si photodiode

spectral range

(400 - 1100) nm

Miscellaneous
Mounting

M6 threaded hole

Connector

coaxial cable 2 m Long, with BNC (-1), calibration data (-2) or ITT (-4) connector

temperature range

(5 - 40) °C

Type Description File-Type Download
Datasheet ISD-3P-Si PDF
Produktname Product Image Description Show product
P-9710 High-quality device for measurement of CW-, single pulse and modulated radiation.

Features: Optometer for all detector heads with calibration data plug. Measurement modes: CW, pulse energy, dose, peak-to-peak, effective luminous intensity (Blondel-Rey), data logger, battery, main power, RS232
X1 Four-channel USB optometer designed for mobile use.

Features: Compact device for use with all photometric, radiometric, colorimetric, plant-physiologic and photo-biologic measurement heads from Gigahertz-Optik. USB interface. Battery operation or power supply USB.
X1-RM Optometer in 3HE housing for use in 19” racks.

Features: Its USB and RS232 remote interface and two additional RS232 device interfaces make the device highly flexible when it comes to system integration. Its four signal inputs enable use with all photometric, radiometric, colorimetric, plant-physiologic and photo-biologic measurement heads from Gigahertz-Optik.
X1-PCB Optometer module.

Feature: The X1 optometer is available as a printed circuit board either with or without a housing and is suited for applications that do not require a keyboard or display. Four signal inputs enable connection with all measuring heads from Gigahertz-Optik.
P-2000 Two-channel optometer.

Features: For use with most photometric and radiometric detectors supplied by Gigahertz-Optik. Modes: CW, pulse energy from both single and multiple flashes, effective luminous intensity (Blondel-Rey), data logger and others.
P-9801 Eight-channel optometer.

Features: State-of-the-art 8 channel laboratory optometer with a signal amplifier and sample & hold ADC per channel for clocked recording of the measurement signals. RS232 and IEEE488 interface. Trigger input and output.
P-9802 Light meter for laboratory use with up to 36 measurement heads.

Features: For use with up to 36 photometric and/or radiometric measurement heads. RS232 interface.
TR-9600 High-speed 1µs or 100ns rise time data logger optometer.

Features: Laboratory device for recording of clocked intensity progress readings in single light flashes, flash sequence or modulated light. Calculation of pulse data e.g. peak intensity, pulse length, pulse half width , pulse energy and pulse repeat rate, etc.
P-9202-4 Fast response time trans-impedance signal amplifier.

Features: High quality analogue amplifier with current-voltage conversion. Minimal diode offset voltage for short circuit operations. Bandwidths of up to 330kHZ. 1µs rise time. Large I-U amplification range from 10pA/V to 1mA/V.
P-9202-5 Universal trans-impedance signal amplifier.

Features: High quality analogue amplifier with current-voltage conversion. Minimal diode offset voltage (1mV) for short circuit photodiode operations. 5µs to 20ms rise time depending on the amplification. Large I-U amplification range – 1×10-10A/V to 1×10-3 A/V.
P-9202-6 Highly sensitive trans-impedance signal amplifier.

Features: High quality analogue amplifier with current-voltage conversion with minimal diode offset voltage (0.5mV) for short circuit photodiode operation of . 2.5s to 25s rise time depending on the amplification. Large I-U amplification range – 1×10-11A/V to 1×10-4 mA/V.
Article-Nr Modell Description Request / Compare
Product
15298321 ISD-3P-Si-1 Detector head with -1 connector, calibration certificate
15298322 ISD-3P-Si-2 Detector head with -2 connector, calibration certificate
15298323 ISD-3P-Si-3 Detector head with -4 connector, calibration certificate
Re-calibration
15300251 K-ISD3PSi-SD

Re-calibration of spectral radiant power responsivity in A/W with calibration certificate

Options
101219 UM-DP-11 additional detector port
Accessories
100929 UFC-11-SMA