GB-GD-360-RB40 goniometer for 2π sources

Measurement of Radiant Intensity / Luminous Intensity

Irradiance/Illuminance detectors such us Gigahertz-Optik’s RW-37, UV-37, PD-9304, PD-9304 with PD-93RW can be used to measure radiant/luminous intensity of spot sources by converting measured irradiance by the inverse square law.

Measurement of Radiant Intensity / Luminous Intensity Distribution 

Combined with the GB-GD-360-RB40 goniometer bench irradiance/illuminance detectors can also be used to measure the radiant/luminous intensity distribution of hemispherical emitting (2π) light sources.

Variable Measurement Distance 

The GB-GD-360-RB40 goniometer is set-up with a up to three meter long rail benches (other sizes on request). Adjustment of the measurement distance between test source and detector from 100 mm to about 3 m is possible. This unique feature enables spatial distribution measurement of single LEDs as well as of larger size LED matrices or luminaires. 


Remote Control Operation 

Goniometer and light meter are remote PC controlled by Gigahertz-Optik’s S-XX software (e.g. S-BTS2048). The measurement sequence can be set in symmetrical or individual steps. Measurement data includes the spatial radiant intensity and data transfer into IES and EULUMDAT format. Also total radiant power or total luminous flux is calculated from the accumulated radiant/luminous intensity distribution data. Furhtermore 2D polar plots or 3D intensity distribution plots are available.

For more detailed information on the software and hardware please refer to their respective datasheets.
GB-GD-360-RB40
Product
Measurement distance

GB-GD-360-RB40-1: (100 to 900) mm

GB-GD-360-RB40-2: (100 to 1900) mm

GB-GD-360-RB40-3: (100 to 2900) mm

max. sample length

100 mm

Horizontal Resolution

0.1°

Axial Resolution

0.2°

max. load

1.5 kg

Interface

RS232/RS485

Type Description File-Type Download
Datasheet GB-GD-360-RB40 PDF
Produktname Product Image Description Show product
BTS256-LED-DA Compact Bi-Tec measurement device for the measurement of illuminance and luminous flux.

Features: Bajonett adapter with diffusor for the BTS256-LED, +/- 30° cosine corrected field of view, spectral radiant power, color temperature, CRI, chromaticity coordinates, etc.
BTS256-E Mobile meter for the measurement of illuminance and light color.

Features: Mobile meter, datalogger, splash-proof, spectral irradiance, photopic, scotopic and melanopic illuminance, spectral irradiance, CCT, CRI, color coordinates, Option: WiFi, etc.
BTS2048-VL Bi-technology sensor light meter for high speed LED binning.

Features: High spectral resolution, short measurement time (electronic shutter), high dynamic (filter wheel), Trigger input and output, entrance optic with diffusor for illuminance and spectral irradiance, CCT, CRI, color values, etc.
VL-3701 Detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 3 %, f2 ≤ 1.5 %, 0.5 nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

VL-3702 Detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 6 %, f2 ≤ 3 %, 0.5 nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

VL-3704 Detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 5 %, f2 ≤ 3 %, 20pA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

VL-3705 Detector head for the measurement of scotopic illuminance in Lux [lx].

Features: f1 ≤ 5 %, f2 ≤ 3 %, 0.2nA/lx, 20mm height, for the usage with Optometers and amplifiers, calibration certificate

PD-9310A High sensitive detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 3 %, 2.8nA/lx, 20mm diffuser, for the usage with optometers and amplifiers, calibration certificate

PD-9310B High sensitive detector head for the measurement of photopic illuminance in Lux [lx].

Features: f1 ≤ 6 %, 2.8nA/lx, 20mm diffuser, for the usage with optometers and amplifiers, calibration

PD-9304 Universal detector head for LASER power, illuminance and 400-1100 nm iiradiance.

Features: Si-photodiode with 1 cm², exchange able filters and cosine diffuor, for the usage with optometers and signal amplifiers

RW-3701 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 400-500nm (BLUE), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3702 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 700-800nm (RED), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3703 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 400-800nm (VIS), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3704 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 800-1000nm (NIR), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
RW-3705 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 400-1000nm (VISNIR), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

RW-3708 Detector head for the measurement of irradiance in W/m².

Features: spectral responsivity from 950-1700nm (NIR), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3701 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 315-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
UV-3702 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 280-315nm (UV-B), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3703 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 200/250-280nm (UV-C), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3710 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 320-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
UV-3711 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 280-320nm (UV-B), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3716 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 305-400nm (UV-A), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.
UV-3717 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 315-400nm (UV-A), low cross talk from radiation > 400 nm, cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3719 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 250-400nm (UV), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

UV-3720 Detector head for the measurement of irradiance of UV radiation in W/m².

Features: spectral responsivity from 240-320nm (UV), cosine field-of-view, for the usage with optometers and amplifiers, calibration certificate.

S-SDK-GB Software Development Kit for GB variants (goniometer).
Article-Nr Modell Description Request / Compare
Product
15298667 GB-GD-360-RB40-1

To measure the luminous intensity and radiant intensity distribution. Photometer bench B2S-40-M1000 with detector holder. Measurement distance 100 mm to 1000 mm. Two axis goniometer GB-GD-360.

15298602 GB-GD-360-RB40-2

To measure the luminous intensity and radiant intensity distribution. Photometer bench B2S-40-M1000 with detector holder. Measurement distance 100 mm to 2000 mm. Two axis goniometer GB-GD-360.

15298853 GB-GD-360-RB40-3

To measure the luminous intensity and radiant intensity distribution. Photometer bench B2S-40-M1000 with detector holder. Measurement distance 100 mm to 3000 mm. Two axis goniometer GB-GD-360.

Software
15298222 S-SDK-GB

Software Development Kit for the implementation of a GB or variants into custom made software