Gigahertz-Optik GmbH
An der Kälberweide 12
D - 82299 Türkenfeld
Telefon:
Fax:
Email:
Fax:
Email:
ISS-8P-V01
ISS-8P-HP
ISS-8P-VA
ISS-8P-VAHP
Modular Variable Integrating Sphere Source
Gigahertz-Optik’s model ISS-8P integrating sphere forms the basis for a modularly configurable uniform light source. It can be combined with the LS-OK30 light source assembly and different types of attenuation devices to meet the requirements for a lab standard calibration source useful for:
- Pixel uniformity and pixel linearity calibration of imaging systems with a large dynamic luminance range
- MTF calibration of imaging sensor resolution where a slit target at a specified distance is uniformly illuminated by the integrating sphere source
- Luminance or spectral radiance sensitivity calibration of imaging devices or luminance meters
Gigahertz-Optik offers three different integrating sphere sources based on the ISS-8P integrating sphere.
Model ISS-8P-HP is set-up with the LS-OK30 light source combined with LS-OK30-FH filter holder and three manually exchangeable LS-OK30-HPA neutral density filters at OD0, OD1 and OD2 attenuation factors corresponding to 100%, 10% and 1% light throughput respectively. A typical application for this set-up is pixel-uniformity calibration of imaging systems at three different luminance or radiance levels. The filter exchange is faster and more precise than intensity adjustment using a variable aperture.
Model ISS-8P-VA is set-up with the LS-OK30 light source combined with manually operated LS-OK30-VA variable aperture for intensity control. Use this system when a precisely controlled luminance or radiance is required.
Model ISS-8P-VAHP is set-up with the LS-OK30 light source plus LS-OK30-VA and LS-OK30-HPA. The variable aperture enables the analogue luminance or radiance whereas the holes pattern attenuator offers attenuation in OD0, OD1 and OD2 steps. In each OD range the range of the variable output is fully controllable a unique feature over integrating sphere sources with a variable aperture only. The ISS-8P-VAHP offers the widest high resolution controllable luminance and radiance range of the three ISS-8P set-ups.
Common Features:
- Hole-pattern attenuation filters have some advantages over metal or interference type neutral density filters since the light signal does not have to pass through any filter material or coating layer. This ensures minimal change on the spectral shape, thus source color temperature. Also hole-pattern attenuators are not subject to temperature drift effects.
- The LS-OK30 light source can be configured with LH-F and LH-F-UV series quartz halogen lamps from 5 to 100W. Lamp power level is selected based on the luminance and radiance level requirements.
- Optional luminance (cd/m²) and/or spectral radiance calibration (W/m²·sr) is performed by Gigahertz-Optik’s calibration laboratory for optical radiation quantities
- Optional lamp power supplies, light meters and monitor detectors are available
Specifications (graphic)
Picture 1: Luminance Uniformity Scan at the 19mm Diameter Light Output Port
ISS-8P-V01 Integrating Sphere for Modularly Configurable Light Source
Picture: Front and Back View of ISS-8P-V01
| Specifications | ||
| Sphere Diameter | 80mm | |
| Sphere Coating | ODM98 | |
| Baffle Diameter | 50mm | |
| Baffle Position | In-line between light input and light output port | |
| Baffle Coating | ODM98 | |
| Light Output Port | 19mm diameter | |
| Light Input Port | 30mm diameter | |
| Light Source Interface | Threaded holes-pattern around the port | |
| Sphere Assembly | Four octagonal flat surfaces with two M6 holes |
| Ordering Information | ||
| Model | Item No.: | Description |
| ISS-8P-V01 | 102759 | Integrating Sphere |
| Options | Description |
| LS-OK30 Series | Light source |
| LS-OK30-VA | Variable attenuator with manual drive |
| LS-OK30-VA-RM | Variable attenuator with stepping motor drive for remote control |
| LS-OK-30-FH | Filter holder |
| LS-OK-30-FHI | Filter holder insert for 2” filters |
| LS-OK30-HPA | Hole-pattern attenuation filter in LS-OK30-FHI filter holder insert |
| Fiber Bundle Adapter | Custom part (contact factory) |
| Monitor Detector | PD-11, VL-11, TD-11 with UMPF-0.5 detector port |
| Lightmeter | X1-RM Optometer for BTH-19 housing |
| LPS-100 | Lamp power supplies for BTH-19 housing |
ISS-8P-HP Integrating Sphere Source
Picture: Front and Back View of ISS-8P-HP
| Specification | ||
| Light Output Port | 19mm diameter | |
| Luminance | 70000 cd/m² at CCT 3100K with LH-100F-UV @ 8.5A and LS-OK30-HPA-OD0 | |
| Lamp Connection | Two Banana type plugs | |
| Sphere Specification | See ISS-8P-V01 |
| Ordering Information | ||
| Model | Item No.: | Description |
| ISS-8P-HP | 102788 | Integrating Sphere Source with three OD0, OD1 and OD2 attenuators. Selectable quartz halogen lamp between 5 and 100W. Mains socket plug-in power supply for cooling fans |
| Options | Description |
| LH-F | Quartz halogen lamps with UV stop bulb from 5 to 90W |
| LH-F-UV | Quartz halogen lamps with UV open bulb from 10 to 100W |
| Monitor Detector | PD-11, VL-11, TD-11 with UMPF-0.5 detector port. Temperature stabilized version TD recommended for use with high power lamps |
| Lightmeter | X1-RM Optometer for BTH-19 housing |
| LPS-100 | Lamp power supplies for BTH-19 housing |
| KLW-P3 | Luminance calibration |
| KLW-S3 | Spectral Radiance calibration |
ISS-8P-VA Integrating Sphere Source
Picture: Front and Back View of ISS-8P-VA
| Specification | ||
| Light Output Port | 19mm diameter | |
| Luminance | 70000 cd/m² at CCT 3100K with LH-100F-UV @ 8.5A and LS-OK30-VA 100% open | |
| Lamp Connection | Two Banana type plugs | |
| Sphere Specification | See ISS-8P-V01 |
| Ordering Information | ||
| Model | Item No.: | Description |
| ISS-8P-VA | 102602 | Integrating Sphere Source with manually operated variable aperture attenuator. Selectable quartz halogen lamp between 5 and 100W. Mains socket plug-in power supply for cooling fans |
| Options | Description |
| LH-F | Quartz halogen lamps with UV blocker envelope from 5 to 90W |
| LH-F-UV | Quartz halogen lamps without UV blocker envelope from 10 to 100W |
| Monitor Detector | PD-11, VL-11, TD-11 with UMPF-0.5 detector port. Temperature stabilized version TD recommended for use with high power lamps |
| Lightmeter | X1-RM Optometer for BTH-19 housing |
| LPS-100 | Lamp power supplies for BTH-19 housing |
| KLW-P3 | Luminance calibration |
| KLW-S3 | Spectral Radiance calibration |
ISS-8P-VAHP Integrating Sphere Source
Picture: Front and Back View of ISS-8P-VAHP
| Specification | ||
| Light Output Port | 19mm diameter | |
| Luminance | 70000 cd/m² at CCT 3100K with LH-100F-UV @ 8.5A, LS-OK30-HPA-OD0 and LS-OK30-VA 100% open | |
| Lamp Connection | Two Banana type plugs | |
| Sphere Specification | See ISS-8P-V01 |
| Ordering Information | ||
| Model | Item No.: | Description |
| ISS-8P-VAHP | 102602 | Integrating Sphere Source with manually operated variable aperture attenuator and three OD0, OD1 and OD2 attenuators. Selectable quartz halogen lamp between 5 and 100W. Mains socket plug-in power supply for cooling fans |
| Options | Description |
| LH-F | Quartz halogen lamps with UV blocker envelope from 5 to 90W |
| LH-F-UV | Quartz halogen lamps without UV blocker envelope from 10 to 100W |
| Monitor Detector | PD-11, VL-11, TD-11 with UMPF-0.5 detector port. Temperature stabilized version TD recommended for use with high power lamps |
| Lightmeter | X1-RM Optometer for BTH-19 housing |
| LPS-100 | Lamp power supplies for BTH-19 housing |
| KLW-P3 | Luminance calibration |