X1-RM Rack Mount Optometer
The X1-RM combines multifunction powerful electronic design in a rack-mountable housing for integration into 19 3HE rack insert modules. A unique feature of the X1-RM is its capability to operate multi-cell light detector heads with up to four photodiodes with all four signals displayed on its four line display with on/off backlighting. The X1-Rms ability to work with most of the Gigahertz-Optik light detector heads enables maximum flexibility in a wide range of radiometric, photometric and colorimetric measurement applications as well as to serve as the reference meter in integrating sphere set-ups used as light sources or OPM measurements. The X1-RM can also control Gigahertz-Optiks LPS family of lamp power supplies via its RS232 or RS485 interface in ISS integrating sphere source or lamp calibration standard systems. Manual operation of the X1-RM is simple. Once set-up all settings are stored and recalled on next power-up unless reprogrammed. Measurement values are displayed in absolute quantities for the particular detector(s) connected. The meter set-up is supported by an easy to use menu. The menu allows selection of the operating mode, the detector and measurement parameter. Beside the manual operation the X1-RM offers remote operation via its USB or RS232 interface (slave mode). The X1-RM firmware is stored in flash-memory allowing simple firmware update via the USB-Interface without loss of the calibration data. The device is powered by 6 - 20 VDC.Specifications (Data)
General Specifications:
Range Specifications:
Detector Interface:
Analogue Voltage Measurement Input:
Operation Overview:
The X1-RM can be manually operated and set-up for measurement using the front panel keypads (3 keys) to access its menu for function selection.
The keys have multiple functions:
key 1: < menu > / < enter >
key 2: < ▲ > / < run > / < stop >
key 3: < ▼ > / < light >
Pressing < menu > key selects the main menu. There are further sub-menus. The up < ▲ > and down < ▼ > arrow keys are used to switch between the different menus. Selecting < escape > aborts menu selection without changing parameters. By pressing < enter > key the menu item displayed is selected. On selecting a setting, the X1-RM requests confirmation ("CHANGE DATA?") to change the parameter. Select < Yes > to confirm that you really want to change the setting.
| Power | 7 - 20 VDC / 100mA; plug 5,5/2,5mm/10mm (+ at middle contact) |
| Display | LCD graphic display 97x32 pixel display area 14.3mm x 35.8mm switchable LED-backlight text display 4 rows each 14 characters |
| Detector interface | 9pin MDSM9 socket, 4 inputs |
| Measurement ranges | seven (200μA to 200.0pA) manual or auto range |
| CW integration time | 1ms - 1s |
| Offset correction | correction range transcending |
| Parameter adjustment | remote control or front panel buttons (menu), adjusted values permanently stored in Eeprom |
| Calibration information | max. 256 Datasets stored in Eeprom |
| Front panel control | 3 buttons, menu system |
| Remote interface | USB V1.1 (HID Device) RS485 or RS232 (factory set) / 19200Baud (Slave Mode) |
| Device control interface | RS485 / RS232 / 19200Baud; DSUB, 9 pins, female LPS and ICP REMOTE 1 and REMOTE 2 |
| Analogue input | 4 voltage measurement channels; 0 - 20VDC, input resistance 1MOhm, 12 bit ADC |
| Temperature | operating: 5 to 40°C storage: -10 to 50° C |
| Size / weight | 65.5mm x 105mm x 80mm / 500g 19", 3HE, 13TE |
| CE conformity | the device conforms with the requirements set out in the council directive on the approximation of the laws of the member states relating to electromagnetic compatibility (89/336/EEC). For the evaluation regarding electromagnetic compatibility, the following standards were applied: EN 61326-1 - Class B |
| Rohs | compatible |
| Warranty | 12 month |
| Range (A/V) | Range max. | Rise time (10 - 90%) | Gain error *) ± offset error (at 20 °C) | Permitted detector capacitance |
| 1x10-4 | ±200.0µA | 3ms | 0.2% ±0.1µA | 2nF |
| 1x10-5 | ±20.00µA | 3ms | 0.2% ±0.01µA | 2nF |
| 1x10-6 | ±2.000µA | 3ms | 0.2% ±0.001µA | 2nF |
| 1x10-7 | ±200.0nA | 3ms | 0.2% ±0.1nA | 10nF |
| 1x10-8 | ±20.00nA | 3ms | 0.2% ±0.01nA | 10nF |
| 1x10-9 | ±2.000nA | 30ms | 0.5% ±2pA | 10nF |
| 1x10-10 | ±200.0pA | 30ms | 0.5% ±2pA | 10nF |
| *) Current calibration of each range by use of a precise current source with DAkks calibration | ||||
| Pin | Function | Function Color |
| 9 | Current Input 1 | X (short) |
| 5 | Current Input 2 | X (long) |
| 1 | Current Input 3 | Y |
| 7 | Current Input 4 | Z |
| 2, 3, 4, 6, 8 | GND | GND |
| Pin | Function | Pin | Function |
| 1 | +UIN1 | 1 | +UIN3 |
| 2 | -UIN1 | 2 | -UIN3 |
| 3 | +UIN2 | 3 | +UIN4 |
| 4 | -UIN2 | 4 | -UIN4 |
The X1-RM can be manually operated and set-up for measurement using the front panel keypads (3 keys) to access its menu for function selection.
The keys have multiple functions:
key 1: < menu > / < enter >
key 2: < ▲ > / < run > / < stop >
key 3: < ▼ > / < light >
Pressing < menu > key selects the main menu. There are further sub-menus. The up < ▲ > and down < ▼ > arrow keys are used to switch between the different menus. Selecting < escape > aborts menu selection without changing parameters. By pressing < enter > key the menu item displayed is selected. On selecting a setting, the X1-RM requests confirmation ("CHANGE DATA?") to change the parameter. Select < Yes > to confirm that you really want to change the setting.
| Menu item | Submenu item | Function |
| 1. Mode | CW | displays the measurement respective of any offset and calibration factors programmed |
| Dose | accumulates the single readings and displays the result as exposure for measured quantity | |
| CIE Yxy & T | displays the CIE Color Values Yxy & T | |
| CIE Yuv & T | displays the CIE Color Values Yuv & T | |
| RS485 Slave | RS485 / RS232 Slave Mode | |
| 3. Setup | Zero Adjust | performs a zero adjustment of the internal amplifier and ADC |
| Integration | sets the measurement (integration) time | |
| Meas. Mode | selects measurement mode (DC, Chopper, Pulse Synchronisation, Peak-Peak) | |
| Dose Time | sets max. dose measurement time | |
| 4. Detector | selects calibration data to calculate the measurement result | |
| 5. Offset | performs an automatic offset adjustment ("Offset = CW" or "Offset = 0") | |
| 6. Range | sets the measurement range (auto, manual) | |
| 7. LPS | Output On | selected power supply LPSxxx output on |
| Output Off | selected power supply LPSxxx output off | |
| Current Set | selected power supply LPSxxx current set (absolute) | |
| Current Adjust | selected power supply LPSxxx current adjust (increment / decrement) | |
| Voltage Set | selected power supply LPSxxx voltage set (absolute, only LPS20 / LPS25) | |
| Voltage Adjust | selected power supply LPSxxx voltage adjust (increment / decrement, only LPS20 / LPS25) | |
| DAC Selection | selected power supply LPSxxx DAC selection (8Bit /16Bit, only LPS25) | |
| Ramp Time | selected power supply LPSxxx Ramp Time (only LPS250 / LPS100) | |
| Error Status | selected power supply LPSxxx Error Status |