Modular light detectors are designed for stand alone use or can be combined with optics and mechanical components to form complete light detector assemblies for a particular application. They offer a mechanical interface which allows accessory components such as optical filters, integrating spheres, diffuser windows and other front-end optics to be easily attached and interchanged.
The TD-11 modular detector series feature thermoelectric temperature stabilization where the detector is heated to a controlled operating temperature of 50°C. The DP-11 front interface enables fast and simple mating of a wide range of accessory components to the detector housing. For multi-purpose use the TD-11 detectors are available with either silicon and InGaAs photodiodes covering the wavelength range from 400 to 1800nm. The detectors are equipped with 2m long coaxial cable with selectable -1, -2 or -4 type connector for use with Gigahertz-Optik’s range of optometers. The control electronics are housed in a separate case and powered by a pug in power supply. Optional calibration of the detector and detectors with accessories are offered by Gigahertz-Optik’s Calibration Laboratory for Optical Radiation Quantities.
Specifications (Data)
TD-11RW03 – T° Controlled & Compact Irradiance Detector Head (W/m²) (400-800 nm)
- Wavelength Range: 400-800 nm
- Control Electronic with external Power Supply
- Operation temperature ~ 55°C
- 29 mm d x 47 mm l Housing
- Typ. Responsivity: x nA/W/m2
- Integrating Sphere Option for Radiant Power Measurement
- Integral Calibration with Broadband Source, spectral Calibration optional
- 2 m Coaxial Cable with -1, -2 or -4 Type Connector
- Extended Cable Length Option (/LC)
- Wavelength Range: 800-1000 nm
- Control Electronic with external Power Supply
- Operation temperature ~ 55°C
- 29 mm d x 47 mm l Housing
- Typ. Responsivity: x nA/W/m2
- Integrating Sphere Option for Radiant Power Measurement
- Integral Calibration with Broadband Source, spectral Calibration optional
- 2 m Coaxial Cable with -1, -2 or -4 Type Connector
- Extended Cable Length Option (/LC)
- Contact Form Light Detectors (English) - 1 MB
- Wavelength Range: 400-1000 nm
- Control Electronic with external Power Supply
- Operation temperature ~ 55°C
- 29 mm d x 47 mm l Housing
- Typ. Responsivity: x nA/W/m2
- Integrating Sphere Option for Radiant Power Measurement
- Integral Calibration with Broadband Source, spectral Calibration optional
- 2 m Coaxial Cable with -1, -2 or -4 Type Connector
- Extended Cable Length Option (/LC)
- Contact Form Light Detectors (English) - 1 MB