Gigahertz-Optik GmbH
An der Kälberweide 12
82299 Türkenfeld / Germany
Phone:
Fax:
Email:
Fax:
Email:
ISD-3P-IGA
Integrating Sphere Laser Power Detector
(Formerly Models LP-0101 and LP-0103)
The ISD-3P laser power detectors are built with a 30mm diameter integrating sphere with 5mm diameter measurement port and synthetic ODM98 coating. The detector is available with two different kinds of photodiode detectors covering different wavelength ranges:
Model ISD-3P-Si is set-up with a silicon photodiode and covers the wavelength range from 400 to 1100nm. Model ISD-3P-IGA is set-up with an Indium Gallium Arsenide photodiode detector and covers the wavelength range from 800 to 1800nm.
The detectors are equipped with a 2m long coaxial cable with selectable -1, -2 or -4 type connector for use with Gigahertz-Optik’s range of optometers. Calibration of spectral radiant power sensitivity in W in 10nm increments within the wavelength range from 400 to 1100 nm or 800 to 1800nm is performed at Gigahertz-Optik’s Calibration Laboratory for Optical Radiation Quantities.
Specifications (Data)
ISD-3P-Si – Laser Power Detector Head (W)
ISD-3P-IGA – Laser Power Detector Head (W)
- Si Photodiode, 350 to 1100 nm Spectral Range
- Integrating Sphere (UPK-30-L) with 30 mm (1.7 in.) dia. and 5 mm (~ 0.2 in.) dia. Port
- Minimized Polarization, Beam “Bounce-Back” and Misalignment
- OP.DI.MA. Coating for High Sensitivity and Long Term Stability
- Spectral Power Calibration in 10 nm Steps with Calibration Certificate
- Typ. Sensitivity 0.6 mA/W at 633 nm
- FC, SC, ST Fiber Optic Adapters for Measurement Port
- Additional SMA-Detector Port for Diode-Array Spectrometer
- Extended Cable Length Option (/LC)
- Optometer: X11, X93, X910, P-9710, P-2000, P-9801, P-9802, TR-9600
- Current to Voltage Amplifier: P-9202
ISD-3P-IGA – Laser Power Detector Head (W)
- InGaAs Photodiode – 800 to 1800 nm Spectral Range
- Integrating Sphere (UPK-30-L) with 30 mm (1.7 in.) dia. & 5 mm (~ 0.2 in.) dia. Port
- Minimized Polarization, Beam “Bounce-Back” and Misalignment
- OP.DI.MA. Coating for High Sensitivity and Long Term Stability
- Spectral Power Calibration in 10 nm Steps with Calibration Certificate
- Typ. Sensitivity 0.4 mA/W at 1300 nm
- FC, SC, ST Fiber Optic Adapters for Measurement Port
- Additional SMA-Detector Port for Diode-Array Spectrometer
- Extended Cable Length Option (/LC)
- Recommended Optometer: X910, P-9710, X11, P-2000, P-9801, P-9802,TR-9600
- Current to Voltage Amplifier: P-9202
Specifications (Graphs)
ISD-3P-Si – Laser Power Detector Head (W)

ISD-3P-IGA – Laser Power Detector Head (W)


ISD-3P-IGA – Laser Power Detector Head (W)

Catalogue complete (English)
- 9 MB