ISD Integrating Spheres Detectors
-
Integrating spheres specifically designed for use with the BTS256-LED tester are described under the BTS256-LED light analyzer.
Integrating Sphere Detectors for use with lightmeters are described under lightmeters.
ISD-50HF-V03 Integrating Sphere for luminous flux. Opens/closes for center mount operation of test lamp inside the 50cm diameter sphere. Lightmeter, light analyzer and calibration optional.
ISD-50HF-V04 Integrating Sphere for luminous flux. Opens/closes plus additional 127mm port. Center mount operation of the test lamp inside the 50cm diameter sphere or outside at port. Lightmeter, light analyzer and calibration optional.
ISD-100HF-V03 Integrating Sphere for luminous flux. Opens/closes for center mount operation of test lamp inside the cm diameter sphere. Lightmeter, light analyzer and calibration optional.
ISD-100HF-V04 V04 Integrating Sphere for luminous flux. Opens/closes plus additional 254mm port. Center mount operation of the test lamp inside the 100cm diameter sphere or outside at port. Lightmeter, light analyzer and calibration optional.
ISD-100HFTO-V01 Integrating Sphere for luminous flux. Test lamp can be mounted in upright, downward or horizontal orientation inside the sphere. Opens/closes plus additional 127mm port for external operation of lamp. Lightmeter, light analyzer and calibration optional.
ISD-10-V01 100mm Integrating Sphere for spot sources, laser diodes and LEDs up to 15mm beam diameter. Barium sulfate coating. UMPA-0.5/11 detector port with diffuser window and baffle. Lightmeter and calibration optional.
ISD-15-V01 150mm Integrating Sphere for spot sources, laser diodes and LEDs up to 25mm beam diameter. Barium sulfate coating. UMPA-0.5/11 Detector port with diffuser window and baffle. Lightmeter and calibration optional.
ISD-21-V01 210mm Integrating Sphere for spot sources, laser diodes and LEDs up to 50mm beam diameter. Barium sulfate coating. UMPA-0.5/11 Detector port with diffuser window and baffle. Lightmeter and calibration optional.
ISD-30-V01 300mm Integrating Sphere for spot sources, laser diodes and LEDs up to 100mm beam diameter. Barium sulfate coating. UMPA-0.5/11 Detector port with diffuser window and baffle. Lightmeter and calibration optional.
ISD-50-V01 500mm Integrating Sphere for spot sources, laser diodes and LEDs up to 127mm beam diameter. Barium sulfate coating. UMPA-0.5/11 Detector port with diffuser window and baffle. Lightmeter and calibration optional.
ISD-100-V01 1000mm Integrating Sphere for spot or beam type sources, laser diodes and LEDs up to 254mm beam diameter. Barium sulfate coating. UMPA-0.5/11 Detector port. Lightmeter and calibration optional